Power:
Line voltages: 100 to 240 VAC
Frequency: 50/60 Hz
DC voltages: n/a
Power consumption:
8 W
Excitation Voltage:
5 VDC, 8 × 350 ohm or 16 × 700 ohm load cells
Analog Signal Input Range:
±7mV/V
Analog Signal Sensitivity:
0.1 μV/graduation minimum,
0. 5 μV/graduation recommended
A/D Sample Rate:
5, 10, 20, 40 Hz, software selectable
Resolution:
Internal: 523,000 counts
Display: 100,000
System Linearity:
Within 0.01% of full scale
Digital I/O:
Optional 2 or 4 inputs
4 or 8 dry-contact relays |
Communication Ports:
Com 1: RS-232 full duplex
Com 2: RS-232 full duplex or 20 mA simplex, continuous
Both ports 1200, 2400, 4800, 9600, 19200, 38400 baud seven or eight data bits, even, odd or no parity
(Optional) Analog Output:
16-bit resolution, voltage output 0-10 VDC, current output 0-20 mA / 4-20 mA
(Optional) Relay Board:
Two opto-isolated, 5 to 24 VDC, active high inputs
Primary keys, pseudo functions, batching functions
(4) 30 VDC, 2 amp dry-contract relays
Annunciators:
Gross, net, center of zero, standstill, lb, kg, tare, preset tare
Display:
480/480 Plus: LED display
0.8 in (20 mm), six-digit, seven-segment
482/482 Plus: LCD backlit display, transmissive/transflective
0.8 in (20 mm), six-digit, seven-segment |
Keys/Buttons:
Flat membrane panel, embossed keys, tactile feel
Temperature Range:
Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Operating: 14 °F to 122 °F (-10 °C to 50 °C)
Rating/Material:
NEMA Type 4X/IP66
Stainless steel
Weight:
6.4 lb (2.9 kg)
Warranty:
Two-year limited
EMC Immunity:
EN 50082 Part 2 IEC EN
61000-4-2, 3, 4, 5, 6, 8, and 11
Approvals:
NTEP CC 12-123, Class III/IIIL, 10,000d
Measurement Canada AM-5892C
OIML R76/2006-NL1-15.24
EU Test Certificate TC8322
CE Marked
cULus
UKCA |
Reviews
There are no reviews yet.